Products

Emerson SDU850B5 Offline UPS 850kVA 510kVA 120/230VAC 1PH

Product Code: SDU850B5

  • Dual voltage input: 120/230 VAC
  • High power capacity: up to 850 kVA
  • Quiet operation: <40 dBA noise level
  • Versatile mounting options: DIN Rail or Chassis
  • Compliant with cRUus, CE, RoHS standards
In Stock Low Stock Out Of Stock Please See Attributes
1

Specifications

Product Type UPS
Brand Emerson
Series SDU AC B-Serie
Application Programmable Logic Controllers Factory Automation Robotics Conveying Equipment Computer based Control Systems
1P / 3P / DC 1P
Battery Monitoring System Battery Warning/Overload Indicator (Red LED): The LED flashes when the battery needs to be recharged and tested.The LED will illuminate when the unit is subjected to an overload condition.If the unit shuts down due to overload, the LED and alarm will continue for two minutes.ON Battery Indicator (Yellow LED): The LED illuminates when the UPS is supplying battery power tothe loads.AC Input Normal Indicator(Green LED): The LED illuminates when the line input voltage is normal.
Communication / Network Card Active Comm Cards (EtherNet/IP, EtherCAT, MODBUS, ProfiNET)
Electrical Endurance Typical Recharge Time: 8 hours Typical Back-Up Time (at full load): 1:30min
kVA / kW (at unity Power Factor) 0.850/510
Maintenance Bypass No
On-board Battery / Seperate Battery Cabinet Sealed, maintenance-free, lead acid batteries
Remote Monitoring UPSwatch
Replacement Batteries Yuasa REW45-12FR
Terminal Type Screw Terminal
Conductor Cross Section Solid Core 8–18 AWG
Tower / Rack / Cabinet Rack
Depth 5.22 in
Height 4.89 in
Weight 11.5 Kg
Width 10.91 in
Operating Temperature without Derating Ordinary Location: 0 to +50 °C (+32 to +122 °F) up to 3000 m (9842.5 ft.)Hazardous Location: 0 to +40 °C (+32 to +104 °F) up to 2000 m (6600 ft.)
Seismic Rated Vibration Operating - IEC60068-2-6, Sine Wave: 10 Hz to 60 Hz displacement of 0.35 mm, 60 Hz to 500 Hz @ 5G;60 min. per axis for all X, Y, Z directionNon-operating - IEC60068-2-6, Random: 5 Hz to 500 Hz@ 2 Grms; 20 min per axis for all X,Y,ZShockOperating - IEC60068-2-27, Half Sine Wave: 10 G for a duration of 10 g for a duration of 10 ms, 3 shockseach in 3 axes in positive and negative directionNon-operating - IEC60068-2-27, Half Sine Wave : 20 g for duration of 10 ms, 3 shocks in 3 axes in positive and negative direction
Storage Temperature -15 °C to +60 °C
IP Rating IP20-rated Input/Output Screw Terminals
Standards and Approvals CE Low Voltage Directive: EN62040-1 EMC Directive:EN62040-2 EN55032; EN 55011, EN55024, EN 61000-6-1,EN 61000-6-2, EN 61000-6-3,EN 61000-6-4, EN 61326-1,EN61000-3-2, EN 61000-3-3,IEC/EN 61000-4 Series UL Recognized Component, UPSEquipment, E179213— UL 1778 5th Ed., CSA C22.2 No. 107.3— Suitable for UL 508 at full load output(no derating) and Ind. ControlEquipment Applications OvervoltageCat III, Pollution Degree IIIUL Recognized Component,Hazardous Locations E491259— ANSI ISA 12.12.01/CSA 213— Class I, Division 2, Groups A, B, C, D, T4ODVA Compliant— EtherNet/IP™ SDUENETIPCARDhas been tested and approved forconformance by the ODVA. Moreinformation about EtherNet/IP™ andthe ODVA can be obtained from thefollowing website: www.odva.org.RoHS Compliant
Products to compare:
Comparing Products