| Product Type |
UPS |
| Brand |
Emerson |
| Series |
SDU AC B-Serie |
| Application |
Programmable Logic Controllers
Factory Automation
Robotics
Conveying Equipment
Computer based Control Systems |
| 1P / 3P / DC |
1P |
| Battery Monitoring System |
Battery Warning/Overload Indicator (Red LED): The LED flashes when the battery needs to be recharged and tested.The LED will illuminate when the unit is subjected to an overload condition.If the unit shuts down due to overload, the LED and alarm will continue for two minutes.ON Battery Indicator (Yellow LED): The LED illuminates when the UPS is supplying battery power tothe loads.AC Input Normal Indicator(Green LED): The LED illuminates when the line input voltage is normal. |
| Communication / Network Card |
Active Comm Cards (EtherNet/IP, EtherCAT, MODBUS, ProfiNET) |
| Electrical Endurance |
Typical Recharge Time: 8 hours Typical Back-Up Time (at full load): 1:30min |
| kVA / kW (at unity Power Factor) |
0.850/510 |
| Maintenance Bypass |
No |
| On-board Battery / Seperate Battery Cabinet |
Sealed, maintenance-free, lead acid batteries |
| Remote Monitoring |
UPSwatch |
| Replacement Batteries |
Yuasa REW45-12FR |
| Terminal Type |
Screw Terminal |
| Conductor Cross Section Solid Core |
8–18 AWG |
| Tower / Rack / Cabinet |
Rack |
| Depth |
5.22 in |
| Height |
4.89 in |
| Weight |
11.5 Kg |
| Width |
10.91 in |
| Operating Temperature without Derating |
Ordinary Location: 0 to +50 °C (+32 to +122 °F) up to 3000 m (9842.5 ft.)Hazardous Location: 0 to +40 °C (+32 to +104 °F) up to 2000 m (6600 ft.) |
| Seismic Rated |
Vibration Operating - IEC60068-2-6, Sine Wave: 10 Hz to 60 Hz displacement of 0.35 mm, 60 Hz to 500 Hz @ 5G;60 min. per axis for all X, Y, Z directionNon-operating - IEC60068-2-6, Random: 5 Hz to 500 Hz@ 2 Grms; 20 min per axis for all X,Y,ZShockOperating - IEC60068-2-27, Half Sine Wave: 10 G for a duration of 10 g for a duration of 10 ms, 3 shockseach in 3 axes in positive and negative directionNon-operating - IEC60068-2-27, Half Sine Wave : 20 g for duration of 10 ms, 3 shocks in 3 axes in positive and negative direction |
| Storage Temperature |
-15 °C to +60 °C |
| IP Rating |
IP20-rated Input/Output Screw Terminals |
| Standards and Approvals |
CE Low Voltage Directive: EN62040-1 EMC Directive:EN62040-2 EN55032; EN 55011, EN55024, EN 61000-6-1,EN 61000-6-2, EN 61000-6-3,EN 61000-6-4, EN 61326-1,EN61000-3-2, EN 61000-3-3,IEC/EN 61000-4 Series UL Recognized Component, UPSEquipment, E179213— UL 1778 5th Ed., CSA C22.2 No. 107.3— Suitable for UL 508 at full load output(no derating) and Ind. ControlEquipment Applications OvervoltageCat III, Pollution Degree IIIUL Recognized Component,Hazardous Locations E491259— ANSI ISA 12.12.01/CSA 213— Class I, Division 2, Groups A, B, C, D, T4ODVA Compliant— EtherNet/IP™ SDUENETIPCARDhas been tested and approved forconformance by the ODVA. Moreinformation about EtherNet/IP™ andthe ODVA can be obtained from thefollowing website: www.odva.org.RoHS Compliant |