Products

Novaris LCP-36 Load Cell Protector 0.25kA 36VDC Panel Mount 116mm W 56mm D 65mm H Aluminium IP65

Product Code: LCP-36

  • Surge protection for 36 VDC systems
  • Compact panel mount design
  • IP65 rated for dust & water resistance
  • Operates in -40 to 85°C temp range
  • Complies with IEC, ITU-T, AS/NZS standards
In Stock Low Stock Out Of Stock Please See Attributes
1

Specifications

General

Product Type
Load Cell Protector
Brand
Novaris
Series
LCP
Application
Signal, Process Control, Loadcells

Electrical

No. of Lines/Pairs
4 or 6
Voltage Protection Level Up
80V
Max. Discharge Current Imax (8/20µs)
0.25kA
Max. Continuous Operating Voltage
24 V AC / 36 V DC

Mechanical

Terminal Size
2.5 mm2

Dimensions & Physical Data

Depth
160mm
Height
56mm
Width
66mm

Environmental

Operating Temperature
-40°C to 85°C
IP Rating
IP67